Free Shipping When You Reach $50
APC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling Solutions
APC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling SolutionsAPC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling SolutionsAPC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling SolutionsAPC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling Solutions

APC 42U InRow RC 600mm Chilled Water Cooling Rack Cabinet - 380-415V 50/60Hz (ACRC602) for Data Center Server Room Cooling Solutions

$20212.82 $36750.59 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:16 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:61639990

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

Manageability

Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Real-Time Capacity Monitoring Real-time display of current and available cooling.

Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

Total Cost of Ownership

Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.

Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.

Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy.

Agility

Casters Provides flexibility to move the unit to wherever cooling is required.

Scaleable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Modular design Modular design provides scalable solutions to add cooling as demand increases.

Serviceability

Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Top